If the values are not the same, use the Client Mover Tool (IPXfer.exe) to restore the communication between the WFBS server and Security Agent. LocalServerPort - must have the same value as Client_LocalServer_Port.ServerPort - must have the same value as Master_DomainPort.Server - must have the same value as Master_DomainName.The values of the following registry keys should be the same as the values from Step 2:.For 64-bit machine: HKEY_LOCAL_MACHINE\Software\WOW6432Node\Trend Micro\PC-CillinNTCorp\CurrentVersion.For 32-bit machine: HKEY_LOCAL_MACHINE\Software\Trend Micro\PC-CillinNTCorp\CurrentVersion.Open the Registry Editor in the offline/disconnected agent and go to the following registry hive:.Look for the following entries, and take note of their values:.